U-values and traditional buildings in situ measurements and their comparisons to calculated values [electronic resource]

By: Contributor(s): Language: English Series: Historic Scotland Technical Paper ; (10)Publication details: Edinburgh Historic Scotland 2011Subject(s): Online resources: Summary: Presents the results of a thermal performance study of traditional building elements, using U-values as an indicator of thermal performance. Measurements were taken in situ, and then compared to computer-generated U-value calculations. Found that such calculations ofted under estimate the thermal performance of traditional building elements.
Holdings
Item type Current library Call number Copy number Status Barcode
Book Virtual Online ONLINE PUBLICATION (Browse shelf(Opens below)) 1 Available 152874-2001

Presents the results of a thermal performance study of traditional building elements, using U-values as an indicator of thermal performance. Measurements were taken in situ, and then compared to computer-generated U-value calculations. Found that such calculations ofted under estimate the thermal performance of traditional building elements.