Evaluation of unventilated pitched roofs with vapour permeable membrane (Record no. 112280)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01750cad a22002175a 4500 |
| 001 - CONTROL NUMBER | |
| control field | L152938 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 110517s2011 xxkd f s f000 0 eng d |
| 020 ## - INTERNATIONAL STANDARD BOOK NUMBER | |
| International Standard Book Number | 9781409828839 |
| 035 ## - SYSTEM CONTROL NUMBER | |
| System control number | (Sirsi) u152938 |
| 041 0# - LANGUAGE CODE | |
| Language code of text/sound track or separate title | eng |
| 110 1# - MAIN ENTRY--CORPORATE NAME | |
| Corporate name or jurisdiction name as entry element | United Kingdom |
| Subordinate unit | Department for Communities and Local Government |
| 9 (RLIN) | 4939 |
| 245 00 - TITLE STATEMENT | |
| Title | Evaluation of unventilated pitched roofs with vapour permeable membrane |
| Remainder of title | final report |
| Medium | [electronic resource] |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Place of publication, distribution, etc. | London |
| Name of publisher, distributor, etc. | DCLG |
| Date of publication, distribution, etc. | 2011 |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | The overall objective of this project when first set out in June 2003, was to investigate current practice in the construction of unventilated roofs with vapour permeable membranes and also to make recommendations for compliance with the recommendations of an amended BS 5250 Code of Practice for control of condensation in buildings. The project objectives had to be revised as the amended BS 5250 anticipated to be published in 2004, was not in fact available until January 2006. The published amended BS 5250 does not consider the situation where it is proposed to provide no ventilation to the roof void, or ventilation more limited than the equivalent continuous low level loft space ventilation opening of 3 or 7 mm depending on how well the ceiling is sealed. Where no ventilation to the roof space is proposed, it is recommended that reference be made to the conditions attached to Technical Approvals given by UKAS (or European equivalent) accredited technical approval bodies. |
| 521 ## - TARGET AUDIENCE NOTE | |
| Target audience note | Advanced |
| 590 ## - LOCAL NOTE (RLIN) | |
| Local note | KA |
| 651 #4 - SUBJECT ADDED ENTRY--GEOGRAPHIC NAME | |
| Geographic name | United Kingdom |
| Chronological subdivision | |
| 690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
| Topical term or geographic name as entry element | BUILT ENVIRONMENT-BUILDING PATHOLOGY |
| 856 40 - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="https://www.communities.gov.uk/documents/corporate/pdf/1898582.pdf">https://www.communities.gov.uk/documents/corporate/pdf/1898582.pdf</a> |
| Public note | View this item free of charge at www.communities.gov.uk |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Suppress in OPAC | 0 |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total Checkouts | Full call number | Barcode | Date last seen | Copy number | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | Virtual | Virtual | Online | 17/05/2011 | ONLINE PUBLICATION | 152938-2001 | 06/08/2019 | 1 | 06/08/2019 | Book |