On the uses and misuses of moisture meters: results from a survey (Record no. 67081)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 01428cam a2200229 4500 |
| 001 - CONTROL NUMBER | |
| control field | ABS63946 |
| 008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION | |
| fixed length control field | 000000n2001 000 0 eng u |
| 035 ## - SYSTEM CONTROL NUMBER | |
| System control number | (Sirsi) u112689 |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Carter, K. |
| 245 ## - TITLE STATEMENT | |
| Title | On the uses and misuses of moisture meters: results from a survey |
| 260 ## - PUBLICATION, DISTRIBUTION, ETC. | |
| Date of publication, distribution, etc. | 2001 |
| 490 ## - SERIES STATEMENT | |
| Series statement | Building Engineer |
| Volume/sequential designation | 76(5) May 2001, 13-17(5) |
| 520 ## - SUMMARY, ETC. | |
| Summary, etc. | Moisture meters, electronic diagnostic tools used to identify the existence of damp problems, are widely used by building surveyors. Describes the results of a study, which included a questionnaire survey of 108 building surveyors, looking at the use and effectiveness of moisture meters. One key finding was that these instruments are often used inappropriately. Explains that although moisture meters provide a quick, low-cost, non-destructive, and relatively accurate method of identifying moisture content in wood they do have limitations that must be taken into account in order to avoid misdiagnosis. Generally calibrated for timber, it is imperative that care is taken in interpreting the figures given by such meters. The study also revealed substantial variations in readings between the different meter types. Graphs. |
| 590 ## - LOCAL NOTE (RLIN) | |
| Local note | ABS |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | MOISTURE METERS |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | SURVEY |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | BUILDING SURVEYORS |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | DAMP |
| 690 ## - LOCAL SUBJECT ADDED ENTRY--TOPICAL TERM (OCLC, RLIN) | |
| Topical term or geographic name as entry element | BUILT ENVIRONMENT-BUILDING PATHOLOGY |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Ahmet, K. |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Suppress in OPAC | 0 |
| Withdrawn status | Lost status | Source of classification or shelving scheme | Damaged status | Not for loan | Home library | Current library | Shelving location | Date acquired | Total Checkouts | Full call number | Barcode | Date last seen | Copy number | Price effective from | Koha item type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Dewey Decimal Classification | London | London | Journal article | 21/05/2001 | ABS63946 | 112689-1001 | 06/08/2019 | 1 | 06/08/2019 | Journal article |